Damage to transformers during transit can go unnoticed until after installation. However, impact monitoring during the move can highlight problems and save considerable time and expense, according to impact monitoring equipment manufacturer SpotSee. 

Earlier this year Kahl Group utilised two Goldhofer modules and a high girder bridge to transport the world's most powerful transformer, a Siemens 1100 kV UHVDC, which had a deadweight of 535 tons (485 tonnes).

To the layperson, a transformer looks like a pretty rugged and durable piece of equipment capable of withstanding all the rigours of transportation and arriving in perfect working order at its destination. After all, they are big, heavy and appear indestructible to the inexpert eye. 

However, transformers are in fact susceptible to damage during transit, especially given that their journeys can cover thousands of miles – sometimes involving less-than-ideal infrastructure – and include multiple handovers between the various logistics teams responsible for getting them from A to B. 

Each of those handoffs represents a risk. If a transformer is dropped, even from a small height of say a few inches, damage may occur. Plus, the heavier it is, the greater the potential for damage.

Most in-transit damage to transformers occurs at low levels of acceleration; those weighing over 100 tonnes, for instance, suffer damage in the 2.5 to 5 g (2-20 Hz) range. 

While on the road, braking and surface conditions can cause mechanical shocks to transformers on trailers, ranging between 0.5 and 1 g in the 3-350 Hz band. 

Rail transport can involve longitudinal impacts of up to 4 g in the 2-20 Hz range during shunting, while rail joints can cause vertical shocks between 0.5 and 1 g in the 2-500 Hz band. 

During ocean transit, transformers can experience rolling, pitching and yawing that cause low-frequency vibrations (typically between 0.3 and 0.8 G in the 2-30 Hz band) that rarely damage them. But pitching and rolling of a ship can reach up to 7 degrees and 45 degrees respectively, potentially loosening cargoes and causing collisions. 

The problem is that the consequences of these incidents may not be apparent. A transformer may even be installed and operating before the damage is noticed. Hidden damage can result in costly repairs or – also expensive – transformer downtime. 

Apportioning responsibility 

Who is responsible for paying the bill? Without data to confirm where and when potentially damage-causing incidents happened, it tends to be the power utility or manufacturer that ends up paying, even though the critical event may in fact have occurred in transit and should, in that case, be covered by the transportation provider’s insurance. 

Tamper-proof impact monitors, which log shocks, vibrations and other information to varying degrees of sophistication, can provide concrete evidence to help insurance inspectors identify the party most likely responsible for damage to a transformer. The data from these devices is accepted as evidence in courts of law. 

The data that impact monitors record can also help engineers to tailor their pre- installation examination of a transformer appropriately, checking it with particular care if it is known to have experienced impacts above a certain threshold, or perhaps streamlining their checks if it is proven to have had an especially smooth journey. 

Impact monitoring can also reduce warranty claims resulting from failures that occur once a transformer is operating. 

The case for mounting impact monitors on transformers is still more compelling when they are shipped to remote locations. In such circumstances, any damage can result in the expensive exercise of flying out a repair team, as returning the unit to the manufacturer for repair may not be a viable option. Instances of returning the transformer are not uncommon, as field repairs cannot cover all issues.

This article is taken from HLPFI's July/August 2018 edition. The content of this article is intended to provide a general guide to the subject matter. Specialist advice should be sought about your specific circumstances.

Heavy Lift | News

Global standard for airfreight of animals launched thumbnail image

Global standard for airfreight of animals launched

April 12 - The International Air Transport Association (IATA) has recently launched a new standardised global certification programme to improve the safety and welfare of animals travelling by air.
Views: 3490
ESTA and FEM summit puts safety in focus thumbnail image

ESTA and FEM summit puts safety in focus

March 8 - The third ESTA and FEM Experts Summit, held in Hamburg on March 6, brought together industry speakers from across the wind energy supply chain to discuss the safety and standards in onshore wind farm construction.
Views: 1881
ESTA and FEM focus on wind turbine safety thumbnail image

ESTA and FEM focus on wind turbine safety

December 20 - Reducing accidents and improving safety during the erection and transportation of onshore wind turbines will be the focus of the third edition of the ESTA and FEM Experts Summit, which will be held in Hamburg on March 6, 2018.
Views: 192
BIMCO submits software maintenance standard thumbnail image

BIMCO submits software maintenance standard

December 15 - The Baltic and International Maritime Council (BIMCO) and Comité International Radio-Maritime (CIRM) have submitted a proposal for an industry-wide standard for software maintenance to the International Maritime Organization (IMO).
Views: 312

Heavy Lift Across The World

Discover heavy lift and project logistics industry news from around the world by region.